COSEL CBS2002412-RF2 is a DC-DC converter from the CBS (200W) series. The specified input voltage range is 18V to 36V. The output voltage is 12V. The listed power rating is 200 W. The maximum output current is listed as 16.7A. The listed efficiency is 87%. The specified isolation voltage is 1.5 kV. The operating temperature range is -40°C ~ 100°C (With Derating). The mounting configuration is Through Hole. Additional technical characteristics: Type: Isolated Module; Size / Dimension: 2.44" L x 2.34" W x 1.04" H (62.0mm x 59.5mm x 26.5mm); Package / Case: Half Brick; Number of Outputs: 1; Features: Remote On/Off, OCP, OVP; Applications: ITE (Commercial). These parameters are based on distributor-listed information and should be confirmed before engineering use.
Specifications
| Applications | ITE (Commercial) |
|---|---|
| Base Product Number | CBS2002412 |
| Current - Output (Max) | 16.7A |
| Efficiency | 87% |
| Features | Remote On/Off, OCP, OVP |
| Manufacturer | Cosel |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| Mounting Type | Through Hole |
| Number of Outputs | 1 |
| Operating Temperature | -40°C ~ 100°C (With Derating) |
| Package | Box |
| Package / Case | Half Brick |
| Power (Watts) | 200 W |
| Series | CBS (200W) |
| Size / Dimension | 2.44" L x 2.34" W x 1.04" H (62.0mm x 59.5mm x 26.5mm) |
| Type | Isolated Module |
| Voltage - Input (Max) | 36V |
| Voltage - Input (Min) | 18V |
| Voltage - Isolation | 1.5 kV |
| Voltage - Output 1 | 12V |
Before ordering
- Minimum and maximum supply voltage, including transients
- Continuous and peak load, cooling and ambient temperature
- Isolation, mechanical envelope and mounting requirements