Flex-Power-Modules
Flex-Power-Modules BMR4920302-861H DC-DC converter
MPN: BMR4920302-861H
Flex-Power-Modules BMR4920302-861H is a DC-DC converter from the BMR492 (600W) series. The specified input voltage range is 40V to 60V. The output voltage is 12V. The listed power rating is 600 W. The maximum output current is listed as 50A. The listed efficiency is 96.80%. The specified isolation voltage is 1.5 kV. The operating temperature range is -40°C ~ 125°C (With Derating). The mounting configuration is Through Hole. Additional technical characteristics: Type: Isolated Module, Digital; Standard Number: 62368-1; Size / Dimension: 2.30" L x 0.89" W x 0.50" H (58.4mm x 22.7mm x 12.7mm); Package / Case: Eighth Brick; Number of Outputs: 1; Features: Baseplate, Heat Sink, I²C Interface, PMBus™, Remote On/Off, Standby Output; Control Features: Enable, Active Floating; Approval Agency: cURus, UL; Applications: ITE (Commercial). These parameters are based on distributor-listed information and should be confirmed before engineering use.
Specifications
| Applications | ITE (Commercial) |
|---|---|
| Approval Agency | cURus, UL |
| Control Features | Enable, Active Floating |
| Current - Output (Max) | 50 A |
| Efficiency | 96.80 % |
| Features | Baseplate, Heat Sink, I²C Interface, PMBus™, Remote On/Off, Standby Output |
| Manufacturer | Flex Power Modules |
| Moisture Sensitivity Level (MSL) | 3 (168 Hours) |
| Mounting Type | Through Hole |
| Number of Outputs | 1 |
| Operating Temperature | -40 °C ~ 125 °C (With Derating) |
| Package | Tray |
| Package / Case | Eighth Brick |
| Power (Watts) | 600 W |
| Series | BMR492 (600 W) |
| Size / Dimension | 2.30" L x 0.89" W x 0.50" H (58.4 mm x 22.7 mm x 12.7 mm) |
| Standard Number | 62368-1 |
| Type | Isolated Module, Digital |
| Voltage - Input (Max) | 60 V |
| Voltage - Input (Min) | 40 V |
| Voltage - Isolation | 1.5 kV |
| Voltage - Output 1 | 12 V |
Before ordering
- Minimum and maximum supply voltage, including transients
- Continuous and peak load, cooling and ambient temperature
- Isolation, mechanical envelope and mounting requirements