P-DUKE-Technology,Inc
P-DUKE-Technology,Inc LCD10-48D12W DC-DC converter
MPN: LCD10-48D12W

Imported data: these values have not been verified against the manufacturer documentation for this exact part number.
P-DUKE-Technology,Inc LCD10-48D12W is a DC-DC converter from the LCD10W (10W) series. The specified input voltage range is 18V to 75V. The output voltage is 12V. The listed power rating is 10 W. The maximum output current is listed as 416mA, 416mA. The listed efficiency is 89%. The specified isolation voltage is 1.6 kV. The operating temperature range is -40°C ~ 105°C (With Derating). The mounting configuration is Through Hole. Additional technical characteristics: Voltage - Output 2: -12V; Type: Isolated Module; Standard Number: 62368-1; Size / Dimension: 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm); Package / Case: 6-DIP Module; Number of Outputs: 2; Features: Adjustable Output, Remote On/Off; Approval Agency: CB, CE, cURus; Applications: ITE (Commercial). These parameters are based on distributor-listed information and should be confirmed before engineering use.
Specifications
| Applications | ITE (Commercial) |
|---|---|
| Approval Agency | CB, CE, cURus |
| Current - Output (Max) | 416 mA, 416 mA |
| Efficiency | 89 % |
| Features | Adjustable Output, Remote On/Off |
| Manufacturer | P-DUKE Technology, Inc. |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| Mounting Type | Through Hole |
| Number of Outputs | 2 |
| Operating Temperature | -40 °C ~ 105 °C (With Derating) |
| Package | Tube |
| Package / Case | 6-DIP Module |
| Power (Watts) | 10 W |
| Series | LCD10 W (10 W) |
| Size / Dimension | 1.00" L x 1.00" W x 0.39" H (25.4 mm x 25.4 mm x 9.9 mm) |
| Standard Number | 62368-1 |
| Type | Isolated Module |
| Voltage - Input (Max) | 75 V |
| Voltage - Input (Min) | 18 V |
| Voltage - Isolation | 1.6 kV |
| Voltage - Output 1 | 12 V |
| Voltage - Output 2 | -12 V |
Before ordering
- DC input range and transients.
- Output voltage, load current and power.
- Efficiency, thermal derating, mounting and isolation if required.