CUI-Inc PDRA-240-48 is a electronic component from the PDRA-240 (240W) series. The output voltage is 48V. The listed power rating is 240W. The maximum output current is listed as 5A. The listed efficiency is 93%. The specified isolation voltage is 3 kV. The operating temperature range is -25°C ~ 70°C (With Derating). Additional technical characteristics: Standard Number: 55024; 55032 Class A; 60950-1; Size / Dimension: 4.72" L x 2.36" W x 4.92" H (120.0mm x 60.0mm x 125.0mm); Number of Outputs: 1; Input Type: AC or DC; Features: Adjustable Output, PFC, Remote On/Off, Universal Input; DC Voltage - Input (Min): 120V; DC Voltage - Input (Max): 370V; Approval Agency: CB Scheme, EN, IEC, UL; Applications: ITE (Commercial); AC Voltage - Input: 85 ~ 264 VAC. These parameters are based on distributor-listed information and should be confirmed before engineering use.
Specifications
| AC Voltage - Input | 85 ~ 264 VAC |
|---|---|
| Applications | ITE (Commercial) |
| Approval Agency | CB Scheme, EN, IEC, UL |
| Base Product Number | PDRA-240 |
| Current - Output (Max) | 5 A |
| DC Voltage - Input (Max) | 370 V |
| DC Voltage - Input (Min) | 120 V |
| Efficiency | 93 % |
| Features | Adjustable Output, PFC, Remote On/Off, Universal Input |
| Input Type | AC or DC |
| Manufacturer | CUI Inc. |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| Number of Outputs | 1 |
| Operating Temperature | -25 °C ~ 70 °C (With Derating) |
| Package | Bag |
| Power (Watts) | 240 W |
| Series | PDRA-240 (240 W) |
| Size / Dimension | 4.72" L x 2.36" W x 4.92" H (120.0 mm x 60.0 mm x 125.0 mm) |
| Standard Number | 55024; 55032 Class A; 60950-1 |
| Voltage - Isolation | 3 kV |
| Voltage - Output 1 | 48 V |
Before ordering
- Minimum and maximum supply voltage, including transients
- Continuous and peak load, cooling and ambient temperature