TRACO-Power

TRACO-Power TEN 40-2433 DC-DC converter

MPN: TEN 40-2433

Photo not yet available

Imported data: these values have not been verified against the manufacturer documentation for this exact part number.

TRACO-Power TEN 40-2433 is a DC-DC converter from the TEN 40 series. The specified input voltage range is 18V to 36V. The output voltage is 3.3V. The listed power rating is 29W. The maximum output current is listed as 6A, 400mA, 400mA. The listed efficiency is 85%. The specified isolation voltage is 1.5kV. The operating temperature range is -40°C ~ 75°C. The mounting configuration is Through Hole. Additional technical characteristics: Voltage - Output 3: -12V; Voltage - Output 2: 12V; Type: Isolated Module; Size / Dimension: 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm); Package / Case: 9-DIP Module; Other Names: TEN 40-2433-ND TEN40-2433; Number of Outputs: 3; Features: Remote On/Off, OCP, OTP, OVP, SCP, UVLO; Detailed Description: Isolated Module DC DC Converter 3 Output 3.3V 12V -12V 6A, 400mA, 400mA 18V - 36V Input; Applications: ITE (Commercial). These parameters are based on distributor-listed information and should be confirmed before engineering use.

Specifications

ApplicationsITE (Commercial)
Current - Output (Max)6 A, 400 mA, 400 mA
Detailed DescriptionIsolated Module DC DC Converter 3 Output 3.3 V 12 V -12 V 6 A, 400 mA, 400 mA 18 V - 36 V Input
Efficiency85 %
FeaturesRemote On/Off, OCP, OTP, OVP, SCP, UVLO
ManufacturerTRACO Power
Moisture Sensitivity Level (MSL)Not Applicable
Mounting TypeThrough Hole
Number of Outputs3
Operating Temperature-40 °C ~ 75 °C
Other NamesTEN 40-2433-ND TEN40-2433
Package / Case9-DIP Module
Power (Watts)29 W
SeriesTEN 40
Size / Dimension2.00" L x 2.00" W x 0.40" H (50.8 mm x 50.8 mm x 10.2 mm)
TypeIsolated Module
Voltage - Input (Max)36 V
Voltage - Input (Min)18 V
Voltage - Isolation1.5 kV
Voltage - Output 13.3 V
Voltage - Output 212 V
Voltage - Output 3-12 V

Before ordering

  • DC input range and transients.
  • Output voltage, load current and power.
  • Efficiency, thermal derating, mounting and isolation if required.